Product Function: Set Temperature ---- SetT;Backlash Temperature-----BackT;1. Heating Mode H:When Temperature SetT - BackT ;Relay conduction, heating equipment begin to work;When Temperature SetT, Relay disconnect, heating equipment stop work;2. Refrigeration mode C:When Temperature SetT BackT ;Relay conduction, refrigeration equipment begin to work;When Temperature SetT ;Relay conduction, refrigeration equipment stop work;3. High Temperature Alarm ALA:When Temperature Alarm Temperature, The system opens the sound and light alarm, and disconnects the relay, any key stops the sound light;4. Delay Start ‘OPH:When a normal heating or refrigeration work is done, the system starts to time T, and only after the TOPH, the system can carry out the next round of heating or refrigeration work;5. Temperature Correction Function OFE(-10.0 ~ 10.0):The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured Calibration;6. Parameter Remote Read/Set:The parameters such as setting temperature, backlash temperature and temperature correction can be set through UART. 7. Real-time Temperature Report: If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;8. Relay enable (default enable):If the relay is disable, the relay remains disconnected;9. Restore factory Settings:At the same time press the STOP, set key more than