Detail Thermostat Hygrometer Digital XY-WTH1 Temperature Humidity Controller
Features: Function of temperature are as follows: 1.The automatic identification of work mode: The system automatically according to the start/stop temperature, identify work mode; Start temperature > stop temperature, cooling mode 'C'. Start temperature < stop temperature, heating mode 'H'. 2.Cooling mode: When the temperature ≥ Start temperature, relay conduction, red led on, refrigeration equipment begin to work; When the temperature ≤ Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work; 3.Heating mode: When the temperature ≤ Start temperature, relay conduction, red led on, heating equipment begin to work; When the temperature ≥ Stop temperature, relay disconnect, red led off, heating equipment stop to work; 4.Temperature correction function OFE (-10.0 ~ 10℃): The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature: 1. In the running interface, Long Press TM+ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM- key, to be modified, waiting for 6s automatic exit and save; 2. In the running interface, Long Press TM- key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM- key, to be modified after the parameters, waiting for 6s automatic exit and save;
The humidity function is as follows: 1.The automatic identification of work mode: The system automatically according to the start/stop humidity, identify work mode; Start humidity> stop humidity, dehumidification mode 'D'. Start humidity< stop humidity, humidification mode 'E'. 2.Dehumidification mode: When the humidity≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work; When the humidity≤ Stop humidity, relay disconnect, green led off, dehumidification equipment stop to work; 3.Humidification mode: When the humidity≤ Start humidity, relay conduction, green led on, humidification equipment begin to work; When the humidity≥ Stop humidity, relay disconnect, green led off, humidification equipment stop to work; 4.Humidification correction function RH (-10.0 ~ 10%): The system is working for a long time and may be biased, through this function correction, the actual humidity = measuring humidity + calibration value;
How to set the start/stop humidity: 1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humidity settings interface, can be modified by RH + RH - key, to be modified, waiting for 6s automatic exit and save; 2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
Package includes: 1 x XY-WTH1 Digital Humidity & Temperature Controller