Ubiquiti PoE Adapters provide a variety of features to help protect your PoE devices:
- Surge protection - Clamping protection - Maximum surge discharge - Peak pulse current - AC cable with earth ground
Electrostatic discharge (ESD) is the leading cause for outdoor device failures. You can effectively protect against ESD damage using a grounded Ubiquiti PoE Adapter, TOUGHCableTM, and TOUGHCable Connectors.
Specifications Model POE-50-60W Dimensions 101 x 60 x 33 mm (3.98 x 2.36 x 1.30”) Weight 192 g (6.77 oz) Output Voltage 50VDC @ 1.2A LAN Activity Indicator No Gigabit LAN Port Yes Remote Reset Capability No Reset Button No Rated Voltage 100-240VAC @ 50/60Hz Input Current 1.3A @ 120VAC, 0.75A @ 230VAC Inrush Current <100A Peak @120VAC, <200A Peak @ 230VAC Efficiency 85+% Output Ripple 1% Max. Switching Frequency 65 kHz Line Regulation ≤ 3% Load Regulation ≤ 5% 2-Pair Powering – 4-Pair Powering Pins 1, 2, 4, 5 (+) and Pins 3, 6, 7, 8 (-) Operating Temperature 0 to 40° C (32 to 104° F) Storage Temperature -30 to 70°C (-22 to 158° F) Operating Humidity 35 to 95% Noncondensing AC Connector IEC-320 C6 Data IN / PoE RJ45 Shielded Socket Surge Protection Difference and Common Mode Clamping Protection 11V Data, 60V Power Max. Surge Discharge 1500A (8/20 μs) Power Peak Pulse Current 36A (10/1000 μs) Data Shunt Capacitance <5 pF data Response Time <1 ns Certifications CE, FCC, IC, UL